Table 3. Local Mode Programming Instructions - Continued

Note: *Default Settings

Function Code(s)

Operation

Normal Indication

Remarks

45
46
47
48

Drawer 1
Open (45)
Closed (46)

Drawer 2
Open (47)
Closed (48)

1. While in programming mode, at the Series 500 Keyboard numeric keypad, enter

applicable Function Code 45, 46, 47 or 48.


LED (2) flashes.


2. At the auxiliary keyboard, press the desired key or type the desired key sequence.

Note that the maximum number of key codes is limited to 24 - this is equivalent to
approximately 12 key strokes.


If the Series 500 Keyboard beeps and
LED (2) turns off while entering key
codes at the auxiliary keyboard, you
have exceeded 24 key codes. Repeat
steps 1 and 2.


3. At the Series 500 Keyboard, press ENTER.

LED (2) turns off.


4. Program the next function code or exit programming mode by entering 99 on Series

500 Keyboard numeric keypad or by swiping the Programmer's card. If using the
optional 3-position keyswitch, move switch out of the AUX position.

49

Poll/
Unsolicited
Cash Drawer Status

1. While in programming mode, at Series 500 Keyboard numeric keypad, enter Function

Code 49.


LED (2) turns on.


2. At Series 500 Keyboard numeric keypad, enter the applicable number (0 or 1) to

select status method per list below.


0 = Send on change or transition

1 = Send only with poll command CDSTATUS

LED (2) turns off.


3. Program the next function code or exit programming mode by entering 99 on Series

500 Keyboard numeric keypad or by swiping the Programmer's card. If using the
optional 3-position keyswitch, move switch out of the AUX position.