48

Table 5. Remote Programming Mode Commands - Continued

OP

CODE

(HEX)

MNEMONIC/DESCRIPTION

COMMAND/ACKNOWLEDGEMENT

B8

MSRSND


Use to send magnetic card reader
track data for any one good track or
if both tracks are good.

COMMAND: B8x<CR>

B8

= Op Code

x

A = send any good track

B = send if both tracks are good

<CR> = terminate command (0D hex)

ACKNOWLEDGEMENT: NONE

B9

CARDED


Enables or disables tracks on
magnetic card reader.

COMMAND: B9c<CR>

B9

= Op Code

c

= track selection

<CR> = terminate command (0D hex)

Track selection:
A

= track 1 on

B

= track 2 on

C

= track 3 on

D

= track 1 and 2 on

E

= track 2 and 3 on

F

= all tracks off


ACKNOWLEDGEMENT: NONE