U-Line CLRCO2075 User Manual

Page 29

Advertising
background image

27

2.

Remove the screws securing the front access panel (Figure 31).

Figure 32

3.

Locate the ice cube thickness adjustment dial on the control board
(Figure 32). Turn the dial clockwise (+ number) to thicken or coun-
terclockwise (- number) to thin the ice bridge.

Ice thickness adjustment dial should be turned only one
increment (number on dial) at a time. Allow the ice maker
to stabilize for 24 hours before making further adjust-
ments. Since ice cubes in any given batch will vary, choose
cubes from the sample area for comparison when making
adjustments (Figure 33). The factory setting is +1.

CLRCO031

0

1

2

-2

3

4

5

-5

-4

-3

-1

DIAL IS FACTORY

SET TO “0”

ICE CUBE THICKNESS

ADJUSTMENT

DIAL

30005_CLRCO2075 User Manual 8/22/03 4:24 PM Page 27

Advertising