Problem

Possible Cause

Remedy

The unit is not

Light staying on.

Call for service.

cold enough.

Dirty condenser coils.

Clean condenser. Refer to
CONDENSER CLEANING.

Airflow to front grille

Airflow must not be

blocked.

obstructed to front grille.
Refer to INSTALLATION.

Temperature not set

Use the temperature

cold enough.

controller to set
temperature colder.
Allow 24 hours for
temperature to stabilize.

Door is not closing

Make sure no obstructions

completely.

are blocking the door and
unit is level. Refer to
LEVELING THE UNIT.
Door adjustment required.
Refer to DOOR
ADJUSTMENT
.

Cycle Selector Switch in

Turn Cycle Selector Switch

OFF position.

to ON.

Temperature

Drain pump blocked.

Check installation and

controller LED

drain line for kinks.

flashing.

Unit malfunction.

Call for service.

Noise during

Certain sounds

Soft sounds from the fan

operation.

are normal.

and water/dropping
sounds from the ice
maker will be heard.

Fresh food section

Temperature control

Use the temperature

on Combo units

set too cold.

controller to set

too cold.

temperature warmer

.

The unit does

Low air temperature

Surrounding air

not operate.

around unit.

temperature must be at
least 50°F (10°C).

Unit runs but no

No water being

Check to see that water

ice is produced.

supplied to the unit.

is connected and turned
on to the unit.