Problem

Possible Cause

Remedy

Unit runs but

Dirty condenser coils.

Clean the condenser.

produces very

Refer to PERIODIC

little ice.

CLEANING AND USER
MAINTENANCE
.

High air temperature

Surrounding air

around unit.

temperature of over
90°F (32°C). Low ice
production at high
temperatures is normal.

Scale and mineral

Clean unit. Refer to

buildup in unit.

PERIODIC CLEANING
AND USER
MAINTENANCE
.

Inadequate airflow at

Remove items blocking

the front of the unit.

airflow.

Cleaning Cycle recently

Allow unit to reach the set

performed.

temperature to produce ice
normally.

Ice is slow to

Ice-making system

Run unit through

release or does

is dirty.

automatic clean cycle.

not release from

Refer to PERIODIC

the evaporator.

CLEANING AND
USER MAINTENANCE
.

Poor ice quality.

Unit is not level.

Refer to LEVELING THE

(soft or unclear)

UNIT.

Poor incoming water

Consult a qualified

quality.

plumber to test the
water quality and
recommend appropriate
treatment.

Ice-making system is

Run unit through

dirty.

automatic clean cycle.
Refer to PERIODIC
CLEANING AND
USER MAINTENANCE
.

41