Serial interface, Sio pass through scheme, Sio (rs232) control setting procedure – Unibrain 830 User Manual

Page 53: Sio (rs232) rx control procedure, Sio(rs232) pass through

Advertising
background image

Unibrain Fire-i 530/630/830 Operation Manual

Page 47

4.9.

Serial Interface

The cameras are equipped with the SIO (Serial input/output) feature described in the IIDC 1.31 specification. By

using the serial interface, the user can execute commands by writing data in a specific address in the FireWire

address range. SIO can be further used as an RS232 interface which supports pass through and custom commands.

4.9.1. SIO Pass Through Scheme

User Target System

SIO(RS232) Pass Through

Camera

FIREWIRE

Cable

RS232C

System

Controller

SIO (RS232) Control Setting Procedure

STEP 1. Configuration of Registers Address : F2F22000h

Baud Rate : 9600, No Parity, 1 bit Stop, 8 bit data length

Write : F2F22000h, Data = 050800000h

Value read after write = 050800020h 20 is the buffer of TX and RX

STEP 2. Enable RS232 TX / RX Address : F2F22004h

Write Data : C00000000 : Now RS232 TX / RX port is enabled

SIO (RS232) RX Control Procedure

STEP 1 Read RBUF_ST of the Receive Buffer Status Control Register (address : F2F22008h) and

check number of RX data buffered in the camera.

If (RBUF_ST !=0) the RX is Ready else RX is NOT Ready

RBUF_ST : The number of current data buffered in the camera (Unit : byte)

RBUF_CNT : READ : Remaining RX buffer size

STEP 2 Write number of RX data intended to read from RBUF_CNT of the Receive Buffer Status

Control Register (address : F2F22008h)

RBUF_CNT can be configured by unit of byte.