Passthrough State: Initiator

Baud Rate

Rate of Passthrough port. Rate can be set to the following (Default =
9600): 110, 300, 600, 1200, 2400, 3600, 4800, 7200, 9600, 14400,
19200, 28800, 38400, 57600, 115200.

Stop Bits

Number of stop bits for Passthrough port (1 or 2).

Parity

None, Even, Odd.

RTS Control

Force OFF, Force ON or Automatic. If automatic, the control will be
on when Passthrough is active. DTR and RTS are available for COM2
only for those VBrick models whose last digit is 3 or higher. Under no
conditions are RTS or DTR controls passed through end-to-end. All
control handling is local. When using a VBrick VCC-3 or VCC-4
camera, set this control to Automatic; when using a VBrick VCC-50i
camera, set this control to Force ON.

DTR Control

Force OFF, Force ON or Automatic. If automatic, the control will be
ON when Passthrough is active. Under no conditions are RTS or DTR
controls passed through end-to-end. All control handling is local.
When using a VBrick VCC-3 or VCC-4 camera, set this control to
Automatic; when using a VBrick VCC-50i camera, set this control to
Force ON.

Operational State

Describes the current status of a Passthrough connection, including
error conditions, if any. Refer to the Network Status Section. This will
display "Active" if in Passthrough mode.