Drive the digital output

Note: This request requires the privilege of viewer.

Method: GET/POST

Syntax:

http://<servername>/cgi-bin/dido/setdo.cgi?do1=<state>[&do2=<state>]

[&do3=<state>][&do4=<state>][&return=<return page>]

Where state is 0, 1. “0” means inactive or normal state while “1” means active or

triggered state.

PARAMETER

VALUE

DESCRIPTION

0 – inactive, normal state

do<num>

0, 1

1 – active, triggered state

return

<return page>

Redirect to the page <return page> after the

parameter is assigned. The <return page> can be

a full URL path or relative path according the the

current path. If you omit this parameter, it will

redirect to an empty page.

Example: Drive the digital output 1 to triggered state and redirect to an empty page

http://myserver/cgi-bin/dido/setdo.cgi?do1=

1

Query status of the digital input

Note: This request requires the privilege of viewer.

Method: GET/POST

Syntax: