Introduction

Tank Gauge Transmitter

2

Installation and Operations Manual

1.3

Operation

The ATT uses an incremental counting technique for determining liquid level. An initial level is identified as part of the

calibration procedure. Changes to that level are determined through incremental increases or decreases detected by

the ATT.

The host computer collects measurement information by polling the Advanced Technology Transmitter over a variety

of communication interfaces such as EIA485 and Mark/Space. Several communication protocols are supported. Among

them are Modbus and Mark/Space.

1.4

Configuration

The Varec Model 1200 Handheld Terminal is used to configure the ATT. It connects to the same ATTI bus used to

interconnect other input/output devices to the ATT. There is a special connection located inside the junction box for

the Handheld Terminal.

1.5

Construction

The Advanced Technology Transmitter is housed within an aluminum enclosure. The enclosure and assembly meet

explosion proof requirements and are environmentally sealed to prevent internal exposure to contamination.

Figure 1-2: Model 4000 Advanced Technology Transmitter Assembly

7.5 "

(190 mm)

12 "

(308 mm)

8 "

(203 mm)

6.8 "

(172 mm)

4 "

(101 mm)

3.4 "

(86 mm)

3.7 "

(94 mm)