Installation

Tank Gauge Transmitter

4

Installation and Operations Manual

2.2

Mounting the Equipment

The ATT is bolted to the Model 2500 Automatic Tank Gauge head as illustrated in Figure 2-2. It may also be mounted

to Endress+Hauser, Sakura, Tokyo-Keiso, Shand & Jurs, and Gauging Systems, Inc. float and tape gauges with the

Endress+Hauser adapter shown in the following table.

Mounting the ATT to the Level Gauge is accomplished in the following manner:

1. Remove the back cover of the Level Gauge.
2. Remove the access cap from the back cover of the Level Gauge.
3. Mount the ATT in place of the access cap, making certain that the word "TOP" cast into the housing lines up with

the top of the Level Gauge back cover.

4. Install the Level Gauge back cover with the transmitter in the Level Gauge. Make certain that the slot in the ATT

drive coupling engages with the pin on the tape sheave of the Level Gauge.

5. Proceed with field wiring.

Figure 2-2: ATT Mounting Diagram

Part Number

Gauge Adapter Kit

13-05956-102

L&J (Shand & Jurs) 92513, 92514, 92020, 92030

13-05956-202

Whessoe 2006, 2026, 2036 and L&J (Shand & Jurs) 92006

Sprocket Sheave

Pin drive

Back

cover

2500

Automatic

Tank Gauge

Transmitter

External enclosure ground

connection by installer

Drive coupling

5/16 split lock washers (4 places)

5/16-18 X 1 mounting bolts (4 places)

Integral junction

box

Junction

box cover

External Ground Lug

Back Cover

Gauge cover mounting

bolts (15 places)