Welch Allyn IMAGETEAM 3800 User Manual

Page 10

Advertising
background image

IMAGETEAM 3800 User’s Guide

1–4

The RS-232 Interface bar code is used when connecting to the serial port of a
PC or terminal. The following RS-232 Interface bar code also programs the
parameters:

Option

Setting

Baud Rate

9600 bps

Parity

Even

Data Format

7 data bits, parity bit, 1 stop bit (8 bit data)

RS-232 Interface

In Wand Emulation mode, the scanner decodes the bar code then sends data
in the same format as a wand scanner. The Same Code format transmits
UPC, EAN, Code 128 and Interleaved 2 of 5 bar codes without any changes,
but converts all other symbologies to Code 39.

Wand Emulation Same Code

The following Wand Emulation bar code sets the interface to Wand Emulation
mode and translates bar code data as Code 39 symbology. It also programs
the Transmission Rate to 25 inches per second, and Output Polarity to black
high.

Wand Emulation (Code 39 Format)

Note for the 3800PDF model:

When the 3800PDF interface is set to wand

emulation, all PDF417 bar code data is transmitted as Code 128. Data from
other symbologies follow the rules described above.