Standard cable pinouts, P2 p1 – Welch Allyn IMAGETEAM 3800 User Manual

Page 114

Advertising
background image

IMAGETEAM 3800 User’s Guide

13–2

Standard Cable Pinouts

Laser Output only

(Laser Compatible Bar Image)

Conventional laser data format is provided at the modular connector in the
scanner handle.

Interface cables are terminated with a 10 pin modular plug (P1) and a 9 pin
Type D (squeeze to release) connector (P2) that is compatible with all Welch
Allyn Data Collection, Inc. terminals. See chart below.

Signal

Function

3
4

1

6

7
2

9

1
2
3

4

5
6
7
8

9

P2

P1

9 Pin Type D Female

10 Pin Modular Plug

Pin 1

Pin 10

6

9

1

5

N/C

Enable

Ground

Good Read

Data

+5VDC

Trigger

SOS

Cord Shield

Laser Enable

Supply Ground

Turn on Good Read LED or Beeper

Digital Bar Code Data Output

5 Volt Power Connection

Trigger Signal to Decoder

Start of Scan

Braid

P1

P2

View A–A

P2 connects to

your terminal.

P1 connects to the
scanner handle.

Pins 4 and 9 are populated depending on power supply voltage option.

N/C

Note: Some decoders may have +12V on pins 4 or 9. Connect to +5VDC
ONLY!

Advertising