Wegener Communications UNITY 4600 User Manual

Page 48

Advertising
background image

U

NITY

4600 U

SER

S

M

ANUAL

800032-01 Rev. F

40

www.wegner.com

R type [page] (Continued)

[page]:

This option can have a value of

1

to

40 and is only applicable for the group status report.

Indicates the page to be reported. If omitted, all eight pages are reported and scrolls off
the terminal screen.

With the

R command, the user gets a combined report of unit non-volatile settings and status and

diagnostics for each item grouping (e.g., RF for all unit settings and all status diagnostics for carrier
acq/tracking). A Local Control Command (available from the terminal regardless of "Local Control
Enable/Disable" commands from the network).

RD group

group:

Indicates group of status/diagnostic information to report, as follows:

AUD

- Audio service diagnos.

AW

- Alarm/Warning status

CA

- Conditional Access diagnostics

DPI

- Conditional Digital Program Insertion (DPI)

GL

- Genlock system (if installed and applicable)

LAN

- IP/Ethernet diagnostics

NTW

- COMPEL

network control diagnostics

PRGMP

- Program mapping at ASI output

MSC

- Miscellaneous diagnostics

REC

- Automated Recovery status

RF

- Carrier Acquisition/Tracking diagnostics

RPA

- Return Path diagnostics

SW

- Software download/self-test status

TS

- Transport Stream diagnostics

VID

- Video service diagnostics

Expanded report on unit volatile diagnostic and status information. A Local Control Command (available
from the terminal regardless of "Local Control Enable/Disable" commands from the network).

RE state [number]

state:

ON

,

OFF

, or

W

number:

1

or

2

, or

E1

thru

E

n (for n-relay expansion option module, if installed) indicating the

affected user relay.

This non-volatile command sets the user (or expansion) relay addressed by number to the

ON/OFF

or

"Follow-Warn" (if '

W

) state specified.

Note: The

W

value for the state parameter is only accepted for the native relays (

1

or

2

).

If state is specified, but number is omitted, then the command is applied to ALL installed relays, with one
exception. The exception is that the command to ALL relays will not be accepted by a native user cue
relay already set in the logical "Follow-warn" state. (It MUST be individually addressed to return it to the

ON

or

OFF

non-volatile state. Entering this command without parameters shows the state of installed

relays.

Table 3.3: Command Directory for U4600 Terminal Commands

Advertising