SP program

program:

Either an integer between

1

and

65,535

(representing a number) or an alphanumeric string

(representing a name), preference being on a number to resolve ambiguity.

Command changes selected

program

by Program Number (from PAT) or SDT descriptor. This command

works similarly to a

PERM command.

TEMP [format] [feed #] [carrier freq] [data rate] [FEC] [Tag Site] program# time

For

format, feed #, carrier freq, data rate, FEC, tag site, and program #, see

PERM

command.

time:

Length of insert in either

HH:MM:SS

format (valid range is

0:00:00

to

18:00:00

, leading zeros

OK to omit on hours) OR in number of seconds. (A one-hour

TEMP

could have a

parameters: of

1:00:00

or

3600

.)

Command which performs a volatile temporary insert for an amount of time given by

time. Unit sets its

temporary Unit Settings to the values given.
Note:No label may be applied using this terminal command.

TEMPCH value time

value:

Either the value of a Preset table entry number OR the Channel Label of an entry, priority
given to Label if any ambiguity. If an entry number, legal values range from

1

up to

N

(where

N

is number of Preset support this product).

time:

Same as for

TEMP

.

Volatile command which sets volatile temporary Unit Settings to those retrieved from the Preset table
according to

value for time given by time. Similar to TEMP command.

TEMPSENS

Command displays internal unit temperature if available.

TEST group value

group:

Mnemonic for a test group: Either

RF

,

AV

,

DTMF

, or

REL

.

value:

Parametric value which has meaning depending on the test group selected.

Command to activate Installation Test Modes. A Local Control Command (available from the terminal
regardless of "Local Control Enable/Disable" commands from the network).
If

group is

RF

, the legal

values are

1

,

2

,

3

,

4

, and

OFF

. Entering numbers for value cause the IRD to report

the RF level (not locked to carrier) at that RF Feed Port every few seconds. Entering

OFF

stops the

measurement.
If

group is

AV

, the legal

values are

ON

and

OFF

. If

ON

, a test pattern is activated on the video output and

test tones activated on the audio output, the same as the generic

TESTMODE

command.

If

group is

DTMF

, the legal

values are

ON

and

OFF.

If

ON

, the command behaves like the

DTMFVOL

command entered with no parameters
If

group is

REL

, the legal

values are

ON

and

OFF

. If

ON

, both user cue relays are alternately energized

and de-energized.

TESTOFF

Command stops all volatile test functions as if unit were reset. A Local Control Command (available from
the terminal regardless of "Local Control Enable/Disable" commands from the network).

Table 3.3: Command Directory for U4600 Terminal Commands