Wegener Communications UNITY 4600 User Manual

Page 50

Advertising
background image

U

NITY

4600 U

SER

S

M

ANUAL

800032-01 Rev. F

42

www.wegner.com

RPATH TO username@addr

username:

Legal string of keyboard characters without white space.

addr:

IP address formatted as

n1:n2:n3:n4

where n

n1

,

n2

,

n3

, and

n4

are integers between

0

and

255

.

Email address destination for Return Path reporting. A Local Control Command (available from the
terminal regardless of "Local Control Enable/Disable" commands from the network).

SAVENV

Saves all the current global and Unit Setting NV parameters (in NVRAM) to the Flash memory space
designated as

BACKUP

.

Note: Some unit-set parameters, which would not make sense to “back up”, may not be saved.
A Local Control Command (available from the terminal regardless of "Local Control Enable/Disable"
commands from the network).

SAVEP [entry#] [channel_label]

entry#:

A Preset Table Entry number or the text,

PERM

. If a preset entry, must be equal to a

number between

1

and

N

inclusive, where

N

is the highest entry number.

channel_label: Channel Label associated with a unit setting or a Preset Table entry. If attempting to

supply the

channel_label

parameter alone, a value of

PERM

is not legal. Parameter must

be a string of continuous non-white-space keyboard characters. Unit will truncate user
input to 10 characters.

Command saves current Unit Settings to a Preset Table entry, or if

entry#

is

PERM

, a current Transient

Setting is loaded into the unit's Permanent unit setting. Those metadata fields in the extended Preset
Entry that have no analog in the current Unit setting will be populated with spec defaults. User must use

ADDE

command to set those fields.

If

entry# is supplied alone, current unit settings are written to that entry, overwriting existing data if it had

been in use. If

channel_label is supplied alone, and if that same Label already appears at a used Preset

Table entry, then the current unit settings overwrite that old Preset data. If

channel_label is supplied

alone and no used Preset has that Label, then the current settings are written to the lowest empty Preset
Table entry and then given that same Label. If both

entry# and channel_label parameters are supplied,

then the current unit settings are written at that Entry (overwriting existing data if any) and that entry is
supplied that same Label (equal to

channel_label).

SERVICE video_pid [pcr_pid] [audio1_pid] [audio2_pid]

video_pid:

Hex value between

20

and

1FFE

.

audio1_pid:

Hex value between

20

and

1FFE

.

audio2_pid:

Hex value between

20

and

1FFE

.

pcr_pid:

Hex value between

20

and

1FFE

.

Command selects A/V services directly by PID number only. This changes Unit Setting #11 to “By PID” if
not already set that way.

Table 3.3: Command Directory for U4600 Terminal Commands