Westinghouse SE 6000 User Manual

Page 86

Advertising
background image

S

ECTION

4: M

ASTER

F

ILE

E

NTRY

4-35

configured for a specific zone and includes the passback feature. In addition, the MOR and the
SE 6000 keep track of the people that are in a specified zone.

E

NTERING

A

M

ULTIPLE

O

CCUPANCY

Z

ONE

When a multiple occupancy zone is vacant, two keyholders are required to present their keys to
the reader to unlock the door; first one and within a prescribed time period, the other, unlocking
the door. Once three or more people are in the multiple occupancy zone, the reader works like a
standard reader, that is, as an individual keyholder with rights presents their key, the door is
unlocked, either entering or leaving.

V

ACATING

A

M

ULTIPLE

O

CCUPANCY

Z

ONE

Vacating a Multiple Occupancy zone, requires that the last two keyholders present their keys at
the same time, first one and then within the prescribed time period the other, unlocking the door.

R

EADER

R

EPORT

D

EFINITION

S

CREENS

The reader report definition screens, [rdr1entr], [rdr2entr], [rdr3entr], and [rdr4entr] are used,
respectively, when setting up a reader to operate with an SE 8xx-series, 422, or NexSentry ACU.
Press F2 after storing the data on the [rdr_entr] screen; the appropriate second screen
automatically displays.

SE 8

XX

-S

ERIES

R

EADER

R

EPORT

D

EFINITION

[rdr1entr]

Reader Mode. Optional. Enter the appropriate reader mode number. This is used for

building modes. The default is 0.

0 = Normal, 1 = Open, 2 = Closed, 3 = Station

The remaining fields, Forced Open through Exit Denied, require a report number entry. The word
report in this context identifies a user-defined action or series of actions that the ACU is to take

1

Advertising