Flip station components, Flip station motor, Flip station viewed from above – Zebra Technologies P640I User Manual

Page 61: Card held by flip arms, Flip station adjustm ent procedu re, Click move truck to flip station, Flip station adjustment procedure

Advertising
background image

980541-001 Rev. A

P640i Card Printer User Guide

51

Flip station components: Upside down views of

the carrier,
drive
component
s omitted.

Flip
station

motor: Viewed from the back of the printer. A
pinion on the motor shaft engages the rack at
the rear of the carrier, above.

Flip
station
viewed
from
above:
Points to
note:

1. The

stop
pin
(integr
al with
the rear
flipper

arm) rests on the bottom edge of the carrier,
alternating from one side to the other in
consecutive flip cycles

2. Azimuth adjust rotates the entire assembly to

bring the flipper arms parallel to the carriage - a
very sensitive adjustment

3. The arms must move freely, without end float.

Over tightening of the screws will lock the arms.

Card held by flip arms : As the carriage moves
into the flip station, the card slides into grooves in the
flip arms. The entire flip assembly is then elevated
clear of the platen.

Flip

station

adjustm

ent

procedu

re

The flip
station
requires no
routine
maintenance
other than
occasional
vacuuming
out of debris.

Typically, there should be no need to alter the factory
settings.

If the flip station ceases to function, or functions
erratically, the technician should perform the
following tests before replacing components.

1. Power OFF.

Remove all cards

from the hopper, then

close the hopper cover. Disable the main cover
interlock so that the printer will function with the
cover open. Power ON.

2. On the host computer follow this sequence:

Start

> Printers (or Printers and Faxes) > Right

click Zebra P640i > Properties > Device Settings
> Control >

Advanced Utilites

3. Click Move Truck to Flip Station.

4. With the flip arms horizontal, click

Flip Test 3

(No

Flip) a few times, noting what happens as the
carrier begins to elevate at the start of the flip
cycle.

This is a test for clearance between flip arms and
platen. If the arms touch the platen, even lightly, there
will be tendency for one or both of them to rotate a
little as the carrier rises. The arms

must

be parallel to

the platen, with a few thousandths of an inch clearance
each side. Using a flashlight, check the gap by
inserting a 0.004" (0.01 mm) feeler gauge between
each arm and the platen. (A narrow strip of regular
copier paper can be used instead, but a long metal
feeler gauge is better.)

Caution • Cards thicker than 0.033"
(0.84 mm) may jam in the flipper arms.