Wt – write tag 37 – Zebra Technologies R2844-Z User Manual

Page 45

Advertising
background image

^WT – Write Tag

The format for the ^WT instruction is:

^WTb,r,m,w,f,v

where the parameters are:

b = block number

Default value: 0
Other values: 1 to n, where n is the maximum number of
blocks for the tag

This is the starting block number. If the user sends more than a block of data it
will overflow into the next block. If the user overflows the block and
subsequent blocks cause errors (write protects, beyond range, etc.), the write
will be aborted, but blocks already written will not revert to original contents.
It’s up to the user to ensure blocks aren’t accidentally overwritten.

r = retries

Default value: 0
Other values: 1 to 10, number of retries

m = motion

Default value: 0 (Feed label after writing)
Other value: 1 (No Feed after writing, other ZPL may cause
a feed)

w = write protect

Default value: 0 (NOT write protected)
Other value: 1 (Write protect)

f = data format

Default value: 0 (ASCII)
Other value: 1 (Hexadecimal)

v =

Not used for this printer.

If there is an error within the data for the transponder, the printer acts
according to the error handling parameter of the RFID Setup command
(^RS).

980476-001A

37

Advertising