^RT – Read Tag

The format for the ^RT instruction is:

^RT#,b,n,f,r,m,s

where the parameters are:

# = number to be assigned to the field

Default value: 0
Other Values: 1 to 9999

b = starting block number

Default value: 0
Other values: 1 to n, where n is the maximum number of
blocks for the tag

n = number of blocks to read

Default value: 1
Other values: 2 to n, where n is maximum number of blocks
minus starting block number. In other words, if the tag has 8
blocks (starting with block 0) and you’re starting with block 6,
n can be 2. This would give you block 6 and block 7
information.

f = format

Default value: 0 ASCII
Other value: 1 Hexadecimal

r = retries

Default value: 0
Other values: 1 to 10, number of retries

m = motion

Default value: 0 (Feed label after writing)
Other value: 1 (No Feed after writing, other ZPL may cause
a feed)

s =

Default value: 0 (Least Significant Byte first)
Other value: 1 (Most Significant Byte first)