Part 1: 02r applications – Yamaha 03D User Manual

Page 10

Advertising
background image

02R Applications

5

Yamaha 02R & 03D Applications Guide

02R

Part 1: 02R Applications

System Operating Notes

02R

02R interface cards must be screwed securely in place. Do not leave the screws out after
installation as the cards will not be grounded correctly.

If a crackling noise can be heard, make sure not more than one device is set to internal
wordclock. One device should be set for internal wordclock (master) and all other
devices should be set to external wordclock (slave).

To see the version number of an 02R, hold down the UTILITY button while turning on
the 02R.

02R Cascade

In a cascaded 02R system, the ID parameter on the Cascade Configuration display must
be set correctly. The setting determines the amount of delay compensation. The ID
parameter is available only when a CD8-CS Cascade card is installed. The ID on the first
02R in a cascade system does not need to be set. In fact, because the IN/OUT switch on
the Cascade card in the first 02R is set to OUT, the ID parameter cannot be set. The next
02R should be set to ID 1, the next to ID 2, and the last to ID 3, as shown below.

The CD8-CS Cascade kit contains two CD8-CS cards and one 25-pin straight cable.

ADAT

To use the ADAT’s DIGITAL INPUT, press the DIGITAL IN button on the ADAT. Do not
press the DIGITAL I/O button on the BRC.

Set the DIGITAL I/O button on the BRC to OFF. This function is for direct ping-pong
between multiple ADATs. If this is turned ON while connected to an 02R, bus
assignments will produce unexpected results. Press the DIGITAL IN button on the
ADAT to use the DIGITAL INPUT.

To check the ADAT wordclock source, press the SET LOCATE and DIGITAL IN buttons
together. The display will show “int” for internal or “digi” for external.

The sampling rate of an ADAT can be set to either 48 kHz or 44.1 kHz. Use Fixed mode
for 48 kHz and Variable mode for 44.1 kHz (using the PITCH DOWN button, set to
–146 cents. At which point 44.1 appears on the display). The newer ADAT-XT has
dedicated switches for selecting these two sampling rates.

02R-A

ID=0

02R-B

ID=1

02R-C

ID=2

02R-D

ID=3

Advertising