Troubleshooting

975-0337-01-01

4–3

Blinking Lights on the Remote Switch

You may encounter different sequences of blinking lights when the
inverter is enabled (i.e., switch is on) or the unit is charging. Light
sequences are described as follows:

Loads stop operating without
warning after they have been
running.
Shorepower is not connected.

Too many appliances have
reduced the battery voltage to
shutdown level.

Ambient temperature is too
high.

Reduce the number of loads.
Allow the inverter to cool and
restart. Recharge the batteries.

Disconnect appliances and let the
unit cool down.

The inverter will not work
even after toggling the switch,
charging the batteries, and
letting the unit cool down.

Remote switch may be
disconnected at the unit

Fuse on the unit (shown in
Figure 1-1) may have blown

Check that the remote switch is
firmly connected.

Replace the fuse or return the unit
to an authorized Xantrex dealer.

AC voltage at receptacles
reads low.

Wrong type of voltmeter being
used.

Use a true RMS meter

In inverter mode, times to
shutdown are getting shorter
for the same kind of AC load

Bad battery cable or corroded
battery terminals.
Batteries too old or damaged.

Check the cables and connectors

Replace the batteries.

Table 4-1

Troubleshooting reference (Continued)

Symptom

Possible Problem

Remedy

Blink Level 1

Fast blink

Light is on for 1/4 second and off for
1/4 second

Blink Level 2

Slow blink

Light is on for 1/2 second and off for
1/2 second

Blink Level 3

Very slow blink

Light is on for one second and off for
one second