Transfer and general specifications – Xantrex Technology IP1012 AL User Manual

Page 41

Advertising
background image

Transfer and General Specifications

975-0337-01-01

A–5

Transfer and General Specifications

Absorption charge voltage

14.3 ± 0.3 Vdc at 77 °F (25 °C)

Float charge voltage

13.3 ± 0.3 Vdc at 77 °F (25 °C)

Temperature compensation – 0.023 Vdc

from -2 °C to 85 °C (28.4 °F to 185 °F).
Below -2 °C, the charger voltage defaults to the –
2 °C voltage

Overvoltage shutdown

Greater than or equal to 15.3 ± 0.3 Vdc

Transfer and general specifications

AC input/bypass current

15 AAC maximum continuous at 122 °F
(50 °C)
Derates to 5 AAC at 185 °F (85 °C)

Transfer speed

10–40 ms typical

AC low voltage transfer

90 ± 5 Vac

AC low voltage restart

95 ± 5 Vac, 30 second delay

AC high voltage transfer

None

Standby/off consumption

< 0.7 watts at 12.5 Vdc with charger and
inverter both off

Operating temperature range

– 40 °F to +185 °F (– 40 °C to +85 °C)

Storage temperature range

– 40 °F to +185 °F (– 40 °C to +85 °C)

Altitude limit

15 000 feet (5000 metres)

AC neutral to ground bonding

Invert mode: AC output neutral is connected
to AC ground (chassis).
Charge mode: AC output neutral is connected
to AC input neutral.

AC input neutral is always isolated from AC
ground.

Charger specifications (Continued)

IP1012_AL.book Page 5 Tuesday, May 1, 2007 12:18 PM

Advertising