Charger specifications – Xantrex Technology IP1012 AL User Manual

Page 40

Advertising
background image

Specifications

A–4

975-0337-01-01

Charger Specifications

All charging specifications are at nominal conditions: 77 °F (25 °C),
14.0 Vdc at 50 A charging, 120 Vac, 60 Hz unless otherwise specified.

Shutdowns and Restarts

DC low voltage shutdown

1.

Battery voltage drops below
10.6 ± 0.15 Vdc at heavy loads (more than
150 W) or 10.8 Vdc at light loads (less than
150 W) for more than 4 min and 10 sec
(± 30 s)

2.

Battery voltage is below 10.4 ± 0.2 Vdc for
3 seconds

DC low voltage restart

13.0 ± 0.15 Vdc

DC high voltage shutdown

16.0 ± 0.2 Vdc

DC high voltage restart

Less than 16.0 Vdc same as DC high voltage
shutdown. There is no hysteresis.

Inverter specifications (Continued)

Charger specifications

Charging method

Three-stage charging with battery temperature
compensation.
See Figure A-3.

Algorithm for generic flooded batteries only

No equalization mode

AC input voltage

100–130 Vac

AC input frequency

54–66 Hz

Minimum battery voltage

7 Vdc
The charger does not operate below this level

Maximum charger input
current

13.0 Aac

rms

Maximum charge rate

50 ± 5 ADC.
See Figure A-2, “Charging current versus
temperature derating curve” on page A–6

Charger efficiency

Greater than 80%

IP1012_AL.book Page 4 Tuesday, May 1, 2007 12:18 PM