Dimension

mm

F

less then 400

Levelling

Use small feet on the bottom of appliance to set same lev-

el of cooker top surface with other surfaces

The stability chain

Caution! You must install the stability chain. If you

do not install it the appliance can tilt.

Before you install stability chain, adjust the appliance to

the correct height.

Measure down 180 mm from the appliance top surface,

then measure right 30 mm (See picture). Mark the posi-

tion of the wall and this gives anchor point for the stability

chain.

30 mm

180 mm

Warning! These instructions are only valid in the

countries whose symbols appear on this booklet's

cover.

Gas Category

I2H

Gas Supply

G20 - 20 mbar

Gas burners

BURNER

NORMAL POWER

NATURAL GAS

kW

inj. 100/mm

Btu/h

Auxiliary burner

1,0

70

3412

Semi-rapid burner

1,9

96

6483

Rapid burner

3,0

119

10236

Grill

2,7

120

9212

Top Oven

1,9

99

6483

Main Oven

1,9

99

6483

Gas Connection

Use a flexible pipe in compliance with the regulation in

force. Be careful they do not come in touch with mobile

parts or they are not squeezed.

Warning! Only a qualified and competent person

must do the gas installation.
Warning! Before gas connection disconnect the

mains plug from the mains socket or switch off the

fuse in the fuse box. Close the primary valve of the gas

supply.

Supply piping should not be less than R3/8. Con-

nection is made to the Rc ½ (1/2 “ B.S.P.) female

threaded. Entry pipe located just below the hob level on

the rear left hand side of the appliance.

The gas supply ramp is on the rear side of the appliance.

Warning! Only liquid sealants to be used when inlet

gas pipe is fitted i.e.: do not use P.T.F.E. sealant

tape.

When installation is complete. Carry out a gas tightness

test and make sure that the seal of each pipe fitting is

correct.