Zanussi ZCG551 User Manual

Page 22

Advertising
background image

Important! Use flexible tubing, which comply with BS.669

current edition.

A

B

C

C

D

E

Warning! The gas bayonet must be in mark area.

Dimension

mm

A

250

B

680

C

50

D

250

E

580

Pressure test

The Rapid injector is used as a pressure test point.
1. Connect the pressure gauge to the Rapid injector.
2. Examine the supply pressure by turning the Rapid

burner and one other burner fully on, and lighting

them. The pressure must be:
a) 20 mbar for Natural Gas
b) 29 mbar for LPG, butane only
c) 37 mbar for LPG, propane only.

3. Turn the taps off and disconnect the pressure gauge.
4. Make sure that all burners work correctly.

Checking the grill

1. Put in the grill pan containing the grid.
2. Light the grill burner by turning the grill control knob

to the symbol .

3. Release the knob when the burner comes on.

Checking the hob burners

1. Lift the lid.
2. Put in the burner crowns and caps. Make sure that

they are correctly seated.

3. Put in the pan supports.
4. Check each of the burners in turn by turning the

burner control knob to the symbol .

5. Release the knob when the burners come on.

Checking the lid shut-off device

1. Lift the lid.
2. Light one of the hob burners.
3. Close the lid. There should be no gas supply to the

hob burners. The burner goes out.

4. Turn the burner off and lift the lid. The gas supply

should be restored to the hob burners, when you turn

the knob on.

Checking the main oven

1. Turn the gas oven control knob to the symbol .
2. When the oven burner comes on, the gas at first flows

to the oven burner slowly, at the FSD by-pass rate.

3. When the FSD heat sensor is heated sufficiently, it

opens the FSD valve. The main gas stream flows to

the burner.

4. After 1 minute make sure that the flame covers the full

width of the burner and is stable.

5. Set the oven control knob to and close the oven

door. After about 10 minutes the flame size should

decrease.

6. Turn the control knob off and check that the oven

flames go out.

Electrical installation

Warning! Only a qualified and competent person

must do the electrical installation.
The manufacturer is not responsible if you do not

follow safety precautions from chapter "Safety infor-

mation".
This appliance is supplied with a main plug and a main

cable.

Connect the phases correctly, if you do not connect,

spark generator will work all the time.

22