3M Multimedia Projector X62w User Manual

Page 77

Advertising
background image

77

Command format
Command formats differ among the different communication ports.
TCP #23
You can use the RS-232C commands without any changes. The reply data format
is the same as the RS-232C commands. However, the following reply will be sent
back in the event of authentication failure when authentication is enabled.

<Reply in the event of an authentication error>

Reply

Error code

0x1F

0x04

0x00

TCP #9715

Send Data format
The following formatting is added to the header (0x02), Data length (0x0D),
Checksum (1byte) and Connection ID (1 byte) of the RS-232C commands.

Header

Data

length

RS-232Ccommand

Checksum

Connection

ID

0x02

0x0D

13 bytes

1 byte

1 byte

Header

→ 0x02, Fixed

Data length

→ RS-232C commands byte length (0x0D, Fixed)

RS-232C commands → RS-232C commands that start with 0xBE 0xEF (13 bytes)
Check Sum

→ This is the value to make zero on the addition of the lower

8 bits from the header to the checksum.

Connection ID

→ Random value from 0 to 255 (This value is attached to

the reply data)

4. Utilize projector – Advanced -

Advertising