Operation, Special information, General information – STIEBEL ELTRON psh 30 trend User Manual

Page 16

Advertising
background image

16

| PSH Trend www.stiebel-eltron.com

Special information

- Install a type-tested safety valve in the cold water

supply line. For this bear in mind that, depending

on the static pressure, you may also need a pres-

sure reducing valve.

- Size the drain so that water can drain off unim-

peded when the safety valve is fully opened.

- Fit the discharge pipe of the safety valve with

a constant downward slope and in a room free

from the risk of frost.

- The safety valve discharge aperture must remain

open to the atmosphere.

oPerATion

1. general information

The chapters "Operation" and "Special Information" are intended

for both the user and qualified contractors.
The chapter "Installation" is intended for qualified contractors.

Note

Read these instructions carefully before using the appli-

ance and retain them for future reference.

Pass on the instructions to a new user if required.

1.1 safety instructions

1.1.1 structure of safety instructions

!

KEYWORD Type of risk

Here, possible consequences are listed that may result

from failure to observe the safety instructions.

f

f Steps to prevent the risk are listed.

1.1.2 symbols, type of risk

Symbol

Type of risk

Injury

Electrocution

Burns

(burns, scalding)

1.1.3 Keywords

Keyword

Meaning

DANGER

Failure to observe this information will result in serious

injury or death.

WARNING

Failure to observe this information may result in serious

injury or death.

CAUTION

Failure to observe this information may result in non-seri-

ous or minor injury.

!