11. commissioning

11.1 commissioning

Note

Fill the appliance with water prior to electrical connec-

tion. If you switch on the appliance while empty, the high

limit safety cut-out will switch it off.

f

f Thoroughly flush out the cold water line before connecting

the appliance, so that no foreign matter gets into the water

heater or safety valve.

f

f Open the shut-off valve in the cold water feed line.

f

f Open a draw-off point until the appliance has filled up and

the pipework is free of air.

f

f Adjust the flow rate. For this, observe the maximum permis-

sible flow rate with a fully opened tap (see chapter "Specifi-

cation / Data table").

f

f If necessary reduce the flow rate at the butterfly valve of the

safety valve.

f

f Turn the temperature selector to maximum.

f

f Switch the mains power ON.

f

f Check the function of the appliance. Ensure that the thermo-

stat switches off.

f

f Check that the safety valve is working correctly.

11.1.1 appliance handover

f

f Explain the function of the appliance and safety valve to

users and familiarise them with their operation.

f

f Make users aware of potential dangers, especially the risk of

scalding.

f

f Hand over these instructions.

11.2 recommissioning

See chapter "Commissioning".

12. shutting down

f

f Disconnect the appliance from the mains at the MCB/fuse in

the fuse box.

f

f Drain the appliance. See chapter "Maintenance / Draining the

appliance".

13. troubleshooting

Note

The high limit safety cut-out can respond at temperatures

below –15 °C. The appliance may be subjected to these

temperatures during storage or transport.

fault

cause

remedy

The water does not heat

up and the ON/OFF indi-

cator does not illuminate.

The high limit safety

cut-out has responded

because the controller is

faulty.

Remedy the cause of the

fault. Replace the con-

troller.

The high limit safety

cut-out has responded

because the temperature

has fallen below -15 °C.

Press the reset button

(see diagram).

The water does not heat

up and the ON/OFF indi-

cator illuminates.

The heating element is

faulty.

Replace the heating el-

ement.

The water does not heat

up sufficiently and the

ON/OFF indicator illumi-

nates.

The temperature control-

ler is faulty.

Replace the temperature

controller.

The heat-up time is very

long and the ON/OFF in-

dicator illuminates.

The heating element is

scaled up.

Descale the heating el-

ement.

The safety valve drips

when heating is switched

off.

The valve seat is contam-

inated.

Clean the valve seat.

Water pressure is too

high.

Install a pressure reduc-

ing valve.