10. installation

10.1 water connection

!

Material losses

Carry out all water connection and installation work in

accordance with regulations.

Operate the appliance only with pressure-tested taps.

10.1.1 Permissible materials

!

Material losses

When using plastic pipework, observe the manufacturer's

data and the chapter "Specification / Fault conditions".

cold water line
Galvanised steel, stainless steel, copper and plastic are approved

materials.

dHw line
Stainless steel, copper and plastic pipework are approved ma-

terials.

10.1.2 Fitting the safety valve

Note

The safety valve supplied must not be used in Belgium.

For use here please use standard safety valves (see also

pricelist).

Note

If the water pressure is greater than 0.6 MPa, install a

pressure reducing valve in the "cold water inlet".

The maximum permissible pressure must not be exceeded (see

chapter "Specification / Data table").

f

f Install a type-tested safety valve in the cold water supply

line. Please note that, depending on the static pressure, you

may also need a pressure reducing valve.

f

f Size the drain so that water can drain off unimpeded when

the safety valve is fully opened.

f

f Fit the discharge pipe of the safety valve with a constant

downward slope and in a room free from the risk of frost.

f

f The safety valve discharge aperture must remain open to the

atmosphere.

10.2 Power supply

WARNING Electrocution

Carry out all electrical connection and installation work

in accordance with relevant regulations.

Before any work on the appliance, disconnect all poles

from the power supply.

WARNING Electrocution

Only use a permanent connection to the power supply.

The appliance must be able to be separated from the

power supply by an isolator that disconnects all poles

with at least 3 mm contact separation.

WARNING Electrocution

Ensure that the appliance is earthed.

!

Material losses

Observe the type plate. The specified voltage must match

the mains voltage.

Power cable

DANGER Electrocution

The power cable must only be replaced (for example

if damaged) with the original spare part by a qualified

contractor authorised by the manufacturer.

The appliance is supplied with a flexible power cable with wire

ferrules and without plug, ready to connect.

f

f If the power cable is of insufficient length, unclamp it from

the appliance. Use a suitable installation cable.

f

f When routing the new power cable, ensure that it is water-

proof as it passes through the existing cable grommet, and is

correctly routed and connected inside the appliance.

Advertising