Operation settings, Settings, Cleaning, care and maintenance – STIEBEL ELTRON psh 30 trend User Manual

Page 18: Troubleshooting, 1 holiday and absence

Advertising
background image

oPerATion

Settings

18

| PSH Trend www.stiebel-eltron.com

4. settings

The temperature can be freely adjusted.

max

D

00000

37

146

2

1

1

ON/OFF indicator

2

Temperature selector

*

Frost protection

E

Recommended energy saving position, low scaling, 60 °C

Max Maximum temperature setting, 75 °C
Depending upon the system, the actual temperatures may vary

from the set value.

on/oFF indicator
The ON/OFF indicator illuminates when water is being heated.

4.1 Holiday and absence

f

f If the appliance is not to be used for a few days, set the tem-

perature selector to a position between the frost protection

and energy saving settings.

f

f If the appliance is not to be used for a longer period, set it to

frost protection to conserve energy. If there is no risk of frost

you may disconnect the appliance from the power supply.

f

f For reasons of hygiene, heat up the content of the water

heater once to above 60 °C before initial use.

5. cleaning, care and maintenance

f

f Have the electrical safety of the appliance and the function of

the safety valve regularly checked by a qualified contractor.

f

f Have the protective anode initially checked by a qualified

contractor after the first year. The qualified contractor will

then determine the intervals at which it must be checked

thereafter.

f

f Never use abrasive or corrosive cleaning agents. A damp

cloth is sufficient for cleaning the appliance.

scaling

f

f Almost every type of water will deposit lime at high temper-

atures. This settles inside the appliance and affects both the

performance and service life. The heating elements must

therefore be descaled from time to time. A qualified contrac-

tor who knows the local water quality will tell you when the

next service is due.

f

f Check the taps/valves regularly. You can remove limescale

deposits at the spouts using commercially available descaling

agents.

f

f Regularly activate the safety valve to prevent it from becom-

ing blocked e.g. by limescale deposits.

6. troubleshooting

Problem

cause

remedy

The water does not heat

up and the ON/OFF indi-

cator does not illuminate.

There is no power.

Check the fuses/MCBs in

your fuse box.

The water does not heat

up sufficiently and the

ON/OFF indicator illumi-

nates.

The temperature is set

too low.

Select a higher temper-

ature.

The appliance heats,

for example, after large

amounts of DHW have

been drawn.

Wait until the ON/OFF

indicator goes out.

The flow rate is low.

The aerator in the tap or

shower head is scaled up

or contaminated.

Clean and/or descale the

aerator or shower head.

If you cannot remedy the fault, notify your qualified contractor. To

facilitate and speed up your enquiry, please provide the numbers

from the type plate (000000 and 0000-000000):

E-NO.: 000000

F-NO.: 0000-000000