Measuring Principle

The glucose dehydrogenase converts the glucose in a blood sample to gluconolactone. This reaction
liberates an electron that reacts with a coenzyme electron acceptor, the oxidized form of the mediator
hexacyanoferrate (III), forming the reduced form of the mediator, hexacyanoferrate (II). The test strip employs
the electromechanical principle of biamperometry. The meter applies a voltage between two identical
electrodes, which causes the reduced mediator formed during the incubation period to be reconverted to an
oxidized mediator. This generates a small current that is read by the meter.

References

1. Stedman’s Medical Dictionary, 27th Edition, 1999, pg. 755.

2. American Diabetes Association, Clinical Practice Recommendations 2003, Diabetes Care, Vol. 26,

Supplement 1, pg. S22.

Chapter 6: Technical Information

Accu-Chek Customer Care 1-800-858-8072

Additional Supplies

The following supplies and accessories are available from your authorized Roche Diagnostics Diabetes
Healthcare Center, pharmacies or your medical/surgical supply dealer:

Test Strips

Accu-Chek Comfort Curve Test Strips

Cat. Nos. 2030365, 2030373, 2030381, 2030420,
3000133, 3000141, 3000150

Accu-Chek Advantage Test Strips

Cat. Nos. 336, 338, 551, 553, 966, 787

Control Solutions

Accu-Chek Comfort Curve
Glucose Control Solutions

Cat. Nos. 2030390, 2030403, 2030411

Lancets

Accu-Chek Softclix Lancet Device

Cat. No. 957

Accu-Chek Softclix Lancets

Cat. No. 971 (100/box)

Accu-Chek Softclix Lancets

Cat. No. 988 (200/box)

blend at bottom is process of PMS
877 with “Chapter 6:...” reversed
out to white throughout chapter 6.

“Additional Supplies ” is process
of PMS 877.

all other text prints black.

blend at bottom is process of PMS
328 with “Chapter 6:....” reversed out
to white and is throughout chapter 6.

blend towards top is process of PMS
124. Triangle with “!” reversed to white
is process of PMS 207.

“Information for...” and “References”
are process of PMS 877.

all other text prints black.

362-17014 Silver Adv OB 3/27/03 6:00 PM Page 40

Advertising