4.

Acroprint Terminal Configuration

Each clock is capable of communicating through any of the two ports it has, one is the RS232
found in all clocks; the other is either the RS485 for networks or the internal modem.

4.1. Configuration Through Badge

The program has several variables that are configurable through the Configuration Badge.
These variables are:

Date
Time
Port

The terminal’s identification can be changed through the Configuration Badge. This
badge has a special number and is used only for this purpose. It must have the number
000000000, and it must be a magnetic stripe type of badge to be considered a
configuration badge. When the clock detects this type of badge, the screen will have the
following options:

Select Option
1-Date 2-Ports 3-Readers 4-Test 5-Initialization 6-FIU Reset

To select, the key with the number chosen must be pressed, <Enter> is not required. A
beep will sound to acknowledge the reception of the entry. The program will wait up to
10 seconds to receive an entry. If this does not happen, it will return to normal execution.

4.1.1. Configuring Procedure for entering the Date and Time

Swipe the Configuration Badge 000000000
(This badge is provided with each terminal.)

Select option 1 for DATE <Press ENTER>

Select the Day, Month, Year, DDMMYYYY <Press ENTER>

Select the Time HH:MM <Press ENTER>
(Time is entered in military time, 2:00 pm = 14:00)

4.1.2. Configuring Procedure for Selecting Ports

Swipe the Configuration Badge 000000000
(This badge is provided for each terminal.)

Select option 2 for Ports < press ENTER>

Select option 0 for RS232 <press ENTER>

Select the baud rate 0 for 1200, 1 for 2400, 2 for 4800, 3 for 9600 and 4 for
19,200 baud. <press ENTER>