Acrocomm programming manual – Acroprint AcroComm User Manual

Page 35

Advertising
background image

AcroComm Programming Manual

The access window is a period of time when the access signal will be
continuously on.

6.2.6. AX

Access Control Mode

Format:

AX=N

where

N:

can be 0-No access, 1-Automatic, 2-Permanent Access

6.2.7. BC

Badge Security Prefix

Format:

BC=XXXX...

where XXXX... is the prefix that all badges must have. The instruction ‘BC=’
disables this validation criteria.

6.2.8. BL

Badge Length, Badge Type

Format:

BL=NN,X

where NN is the badge length allowed ( 1 - 10) and X is the badge type (A=
Alpha Numeric and N= Numeric). The clock will read badges only when they
have a length equal to the value specified in BL (See BM below). Every time
BL is issued, then BN is reset to BL.

6.2.9. BM

Maximum Badge Length

Format:

BM=NN[,F]

where

NN:

Maximum length of badge allowed ( 1 - 40 )

F:

Offset of the starting character within the badge
number to start reading the NN characters.

The terminal will store BL characters of the total badge length (BM), starting
at the offset position. The terminal will read all badges with a length between
BN and BM, but will only store BL characters.

6.2.10. BN

Minimum Badge Length

Format:

BN=NN

where

NN:

Minimum length of badge allowed ( 1 - 40 )

The terminal will read all badges with a length between BN and BM, but will
only store BL characters. Every time BL is issued, then BN is reset to BL.

35