6.2. Command List Formats

The configuration instructions format that are allowed to be sent are listed below:

6.2.1. AC

Access Table Entry

Format:

AC=FGGGGG

where

F:

1-first

record,

0-subsequent

GGG..:

Badge number, or ‘A’ to give access to all badges

An entry of AC=0 will erase the Access Table

6.2.2. AD

Access Signal Length

Format:

AD=NNN

where

NNN:

Access Signal Length in tenths of second. This is also
the signal duration when the external light box is in
use.

6.2.3. AO

Access Only Clock

Format:

AO=X

where X can be ‘Y’ or ‘1’ for Yes, or ‘N’ or ‘2’ for No. When the clock is
‘access only’ the transactions are not stored

6.2.4. AT

Update Date and Time

Format:

AT=NNN

where NNN can be the time difference between the computer and the clock in
hours.

If NNN=0 then “AT” is enough. This instruction retrieves the date and time
from the computer, adds the time difference and sends it to the clocks to
update their date and time

6.2.5. AW

Access Window

Format:

AW=HHMMHHMMDDDDDDD

where

HH:

Access window start hour

MM:

Access window start minute

HH:

Access window end hour

MM:

Access window end minute

DDDDDDD:

Days of the week the access window will be active