Pc_to_rdr_setparameters – ACS ACR3801 Smart Card Reader User Manual

Page 18

Advertising
background image

ACR3801 – Reference Manual

[email protected]

Version 2.01

www.acs.com.hk

Page 18 of 62

8.1.7.

PC_to_RDR_SetParameters

Sets slot parameters.

Offset

Field

Size

Value

Description

0

bMessageType

1

61h

-

1

dwLength

4

-

Size of extra bytes of this message

5

bSlot

1

-

Identifies the slot number for this

command

6

bSeq

1

-

Sequence number for command

7

bProtocolNum

1

-

Specifies what protocol data structure

follows:
00h = Structure for protocol T=0
01h = Structure for protocol T=1
The following values are reserved for

future use:
80h = Structure for 2-wire protocol
81h = Structure for 3-wire protocol
82h = Structure for I2C protocol

8

abRFU

2

-

Reserved for future use

10

abProtocolDataStructure Byte

array

-

Protocol Data Structure


Protocol Data Structure for Protocol T=0 (dwLength=00000005h)

Offset

Field

Size

Value

Description

10

bmFindexDindex

1

-

B7-4 – FI – Index into the table 7 in

ISO/IEC 7816-3:1997 selecting a

clock rate conversion factor
B3-0 – DI - Index into the table 8 in
ISO/IEC 7816-3:1997 selecting a baud

rate conversion factor

11

bmTCCKST0

1

-

B0 – 0b, B7-2 – 000000b
B1 – Convention used (b1=0 for direct,

b1=1 for inverse) Note: The CCID

ignores this bit.

12

bGuardTimeT0

1

-

Extra Guardtime between two

characters. Add 0 to 254 etu to the

normal guardtime of 12etu. FFh is the

same as 00h.

13

bWaitingIntegerT0

1

-

WI for T=0 used to define WWT

14

bClockStop

1

-

ICC Clock Stop Support:
00h = Stopping the Clock is not

allowed
01h = Stop with Clock signal Low
02h = Stop with Clock signal High
03h = Stop with Clock either High or

Low

Advertising