Blown_fuse – ACS ACR3801 Smart Card Reader User Manual

Page 59

Advertising
background image

ACR3801 – Reference Manual

[email protected]

Version 2.01

www.acs.com.hk

Page 59 of 62

8.3.9.8. BLOWN_FUSE

This command is used to blow the fuse of the inserted card. The fuse can be EC_EN Fuse, EC2EN

Fuse, Issuer Fuse or Manufacturer’s Fuse.
Note: The blowing of fuse is an irreversible process.
Command Format (abData field in the PC_to_RDR_XfrBlock)

Where:

Fuse Bit Addr (2 bytes) Bit address of the fuse. Please refer to the table below for the

correct value.

State of FUS Pin

State of the FUS pin. Should always be 0x01h.

State of RST Pin

State of the RST pin. Please refer to below table for the correct

value.

Fuse Bit

Addr

(High)

Fuse Bit

Addr

(Low)

State of

RST Pin

AT88SC101

Manufacturer Fuse

05h

80h

01h

EC_EN Fuse

05h

C9h

01h

Issuer Fuse

05h

E0h

01h

AT88SC102

Manufacturer Fuse

05h

B0h

01h

EC2EN Fuse

05h

F9h

01h

Issuer Fuse

06h

10h

01h

AT88SC1003

Manufacturer Fuse

03h

F8h

00h

EC2EN Fuse

03h

FCh

00h

Issuer Fuse

03h

E0h

00h


Response Data Format (abData field in the RDR_to_PC_DataBlock)

SW1 SW2

Where:

SW1 SW2 = 90 00h if no error

Pseudo-APDU

CLA INS

Error

Counter LEN

Byte

Address

MEM_L

CODE

Fuse Bit

Addr

(High)

Fuse Bit

Addr

(Low)

State of

FUS Pin

State of

RST Pin

FFh

05h

00h

00h

04h

01h

00h or

01h

Advertising