Read_protection_bits, Acr3801 – reference manual – ACS ACR3801 Smart Card Reader User Manual

Page 42

Advertising
background image

ACR3801 – Reference Manual

[email protected]

Version 2.01

www.acs.com.hk

Page 42 of 62

8.3.6.3. READ_PRESENTATION_ERROR_COUNTER_MEMORY_CARD (SLE

4442 and SLE 5542)

This command is used to read the presentation error counter for the secret code.
Command Format (abData field in the PC_to_RDR_XfrBlock)

Pseudo-APDU

CLA INS

P1

P2

MEM_L

FFh

B1h 00h

00h

04h


Response Data Format (abData field in the RDR_to_PC_DataBlock)

ERRCNT DUMMY 1 DUMMY 2 DUMMY 3 SW1 SW2

Where:

ERRCNT

Error counter. 07h indicates that the last verification is correct. 00h indicates

that the password is locked (exceeded the maximum number of retries).

Other values indicate that the last verification has failed.

DUMMY

Three bytes dummy data read from the card

SW1 SW2

= 90 00h if no error

8.3.6.4. READ_PROTECTION_BITS

To read the protection bits for the first 32 bytes.
Command Format (abData field in the PC_to_RDR_XfrBlock)

Pseudo-APDU

CLA INS

P1

P2

MEM_L

FFh

B2h 00h

00h

04h


Response Data Format (abData field in the RDR_to_PC_DataBlock)

PROT 1 PROT 2 PROT 3 PROT 4 SW1 SW2

Where:

PROT y

Bytes containing the protection bits from protection memory

SW1 SW2

= 90 00h if no error


The arrangement of the protection bits in the PROT bytes is as follows:

PROT 1

PROT 2

P8

P7

P6

P5

P4

P3

P2

P1

P16

P15

P14

P13

P12

P11

P10

P9

..

..

..

..

..

..

P18

P17

Where:

Px is the protection bit of BYTE x in the response data