ACS ACR3801 Smart Card Reader User Manual

Page 19

Advertising
background image

ACR3801 – Reference Manual

[email protected]

Version 2.01

www.acs.com.hk

Page 19 of 62


Protocol Data Structure for Protocol T=1 (dwLength=00000007h)

Offset

Field

Size

Value

Description

10

bmFindexDindex

1

-

B7-4 – FI – Index into the table 7 in

ISO/IEC 7816-3:1997 selecting a clock

rate conversion factor
B3-0 – DI - Index into the table 8 in
ISO/IEC 7816-3:1997 selecting a baud

rate conversion factor

11

BmTCCKST1

1

-

B7-2 – 000100b
B0 – Checksum type (b0=0 for LRC,

b0=1 for CRC
B1 – Convention used (b1=0 for direct,

b1=1 for inverse) Note: The CCID

ignores this bit.

12

BGuardTimeT1

1

-

Extra Guardtime (0 to 254 etu between

two characters). If value is FFh, then

guardtime is reduced by 1 etu.

13

BwaitingIntegerT1

1

-

B7-4 = BWI values 0-9h valid
B3-0 = CWI values 0-Fh valid

14

bClockStop

1

-

ICC Clock Stop Support:
00h = Stopping the Clock is not allowed
01h = Stop with Clock signal Low
02h = Stop with Clock signal High
03h = Stop with Clock either High or Low

15

bIFSC

1

Size of negotiated IFSC

16

bNadValue

1

00h

Only support NAD = 00h


The response to this message is the RDR_to_PC_Parameters message.