Command Format (abData field in the PC_to_RDR_XfrBlock)

Where:

Error Counter LEN

Length of presentation error counter in bits

Byte Address

Byte address of the key in the card

CODE

4 bytes Memory Code


Response Data Format (abData field in the RDR_to_PC_DataBlock)

SW1 SW2

Where:

SW1 SW2

= 90 00h if no error
= 63 00h if there are no more retries

Note: After SW1SW2 = 0x9000h has been received, read back the Application Area can check

if the VERIFY_MEMORY_CODE is correct. If all data in Application Area is erased and is equal

to “0xFFh,” the previous verification is successful.

Pseudo-APDU

CLA INS Error Counter LEN Byte Address MEM_L

CODE

Byte

1

Byte 2 Byte 3 Byte 4

FFh

20h

40h

28h

04h