4-1


Field Operations

1. Once calibration procedure above has been followed, Console will store the

calibration and rate information until new information has been entered.

2. Turn on Controller Console by pressing the On/VR key. Green light above

On/VR key will illuminate when power is on. Pressing the On/VR key twice
will put the unit in VR mode. (See Figure 29) VR will appear on the screen
along with the Rate that is being sent from the computer. Press On/VR key
again to toggle back to manual mode. (All mode and rate changes take effect
with the release of the key.)

Figure 29. Main Operating Screen Set on VR mode

3. To change rates manually whether in manual or in VR mode, simply touch the

Up/Down arrow keys. This will change the Controller to the rate you select
manually. To return to VR, simply touch the On/VR key to toggle back to VR
mode.


4. Engage the hydraulic flow by pushing FORWARD on the tractor remote

hydraulic lever. The remote lever must be LOCKED OPEN in this position to
provide constant flow to the drive motor.


-- John Deere tractors with Sound-Gard

body: Use lever lock clip

to lock lever foward. See your dealer for lock purchase and installation.
-- John Deere 7000 series tractors: Rotate valve detent selector to
motor position to lock lever in forward position.
-- John Deere 8000 series tractors: Set timer to continuous. Push
forward until detent clicks.
--Case

–IH Magnum tractors: Lock lever in forward detent position.

You may need to turn up detent pressure to maximum setting. Do
not tie hydraulic lever past detent position with a tarp strap. See
your dealer for details.
-- Other tractors: Lock lever in forward detent position. See your
dealer for proper instructions for motor control.