Operating instructions – Veris Technologies Precision Rate Controller - Operation Manual User Manual

Page 3

Advertising
background image

1-1

Operating Instructions

Drive Operational Requirements:


Hydraulic System:

Closed center, pressure compensated or load
sensed systems only
Drive will not operate on open-centered
hydraulic systems


Minimum Hyd. Pressure:

2250 psi


Maximum Hyd. Pressure:

3000 psi


Maximum Required Flow:

8.5 gpm


Electrical System:

Voltage:

12 volt DC

Amperage:

4 amperes

Tractor Hookup

Hydraulics:

1) Connect pressure hose (P) to retraction outlet

2) Connect motor return hose (T) to motor return port (if available) or to

extension outlet.


3) Set flow rate at maximum.

4) If tractor is equipped with electro-

hydraulic valves, set timer to “constant” flow.



Electrical:

1) Power can be connected in two different manners:

a) Power port adaptor (PN 19676)


Advertising