3 adjustment without medium – VEGA VEGAMET 513 User Manual
Page 21
VEGAMET 513
21
Settings in the "reduced menu"
Adjustment example
You know the data of the sensor, i.e. you
know that at 0 % filling the sensor delivers a
current of 4.2 mA and at 100 % filling a cur-
rent of 15.5 mA. Enter these values in the
menu items.
6.3 Adjustment without medium
Adjustment without medium means that you
carry out the adjustment independent of the
actual level. For this adjustment procedure
you have to enter two sensor current values
(4 … 20 mA) corresponding to the levels
0 % and 100 %.
Enter in these two menu items the values of
the senor. Use the [+] and [–] keys to set the
values and [OK] to save the values.
0%
at
mA
4,200
100%
at
mA
15,500
TAG-
No. 1
%
xx,x
Param.
TAG-
No. 1
Adjust
ment
with
medium
without
medium
0%
at
mA
4,000
100%
at
mA
20,000
Meas. value
indication
4.2 mA at 0 %
15.5 mA at 100 %