2 mounting steps, 3 mounting steps external housing – VEGA VEGABAR 65 Profibus PA User Manual

Page 13

Advertising
background image

1

2

Fig. 4: Temperature ranges

1

Process temperature

2

Ambient temperature

4

.2 Mounting steps

For mounting VEGABAR 65, a welded socket is required. You can find
these components in the supplementary instructions manual "Welded
socket and seals
".

Use the seal corresponding to the instrument:

- or -

Seal with a suitable resistant seal:

l

Flange connection according to DIN/ANSI

à Screw VEGABAR 65 into the welded socket. Tighten the hexagon

screw on the process fitting with SW 27 (spanner width 27 mm).

Warning:
The housing must not be used to screw the instrument in! Applying
tightening force can damage internal parts of the housing.

4

.3 Mounting steps external housing

1

Mark the holes according to the following drilling template

2

Depending on the mounting surface, fasten the wall mounting
plate with 4 screws

Welding the socket

Sealing/Screwing in

Wall mounting

VEGABAR

65 • Profibus PA

13

4 Mounting

28253

-

EN

-090522