VEGA VEGABAR 65 Profibus PA User Manual
Page 57
-
In the compensated temperature range
0 … +100 °C (+32 … +212 °F)
< (0.05 % + 0.1 % x TD)
-
Outside the compensated temperature
range
< (0.05 % + 0.15 % x TD)
Applies also to instruments with analogue 4 … 20 mA current output and refers to the set span.
Thermal change, current output
<
0.15 % at -40 … +80 °C (-40 … +176 °F)
Long-term stability (similar to DIN 16086, DINV 19259-1 and IEC 60770-1)
Applies to digital interfaces (HART, Profibus PA, Foundation Fieldbus) as well as to analogue
current output 4 … 20 mA. Specifications refer to the set span. Turn down (TD) = nominal
measuring range/set span.
Long-term drift of the zero signal
< (0.1 % x TD)/year
Ambient conditions
Ambient, storage and transport temperature
-40 … +80 °C (-40 … +176 °F)
Process conditions
The specifications to the pressure stage and the product temperature are used as an overview.
The specifications of the type label are applicable.
Pressure stage, process fitting
-
Thread 316L
PN
60
-
Thread Aluminium
PN
25
-
Hygienic fittings 316L
PN
6, PN 10, PN 25, PN 40
-
Flange 316L
PN
16/PN 40 or 150 lb/300 lb
Product temperature
-
Standard
-12 … +140 °C (+10 … +284 °F)
-
with extenation, extended thread or
Clamp 2½"
-12 … +140 °C (+10 … +284 °F)
-
with cooling element
-12 … +180 °C (+10 … +356 °F)
-
with cooling element and screening
sheet
-12 … +200 °C (+10 … +392 °F)
Vibration resistance
mechanical vibrations with 4 g and 5 … 100 Hz
12)
Shock resistance
Acceleration 100 g/6 ms
13)
Electromechanical data - version IP 66/IP 67
Cable entry/plug
14)
-
Single chamber housing
l
1 x cable gland M20 x 1.5 (cable: ø 5 … 9 mm),
1 x blind stopper M20 x 1.5
or:
12)
Tested according to the regulations of German Lloyd, GL directive 2.
13)
Tested according to EN 60068-2-27.
14)
Depending on the version M12 x 1, according to DIN 43650, Harting, 7/
8" FF.
VEGABAR
65 • Profibus PA
57
10 Supplement
28253
-
EN
-090522