22
VEGAFLEX 51P and 52P
Mounting
Material cone
When selecting a mounting location for
VEGAFLEX in the vessel, please remember
that material cones can form in solids, caus-
ing inaccurate measuring results. We recom-
mend selecting a mounting location where the
cable detects an average value of the mate-
rial cone.
VEGAFLEX should be installed at a spot that
takes the filling and emptying apertures of
the vessel into consideration. To compensate
measuring errors caused by the material
cone, you should install the cable at a dis-
tance of
d
/
6
from the vessel wall or vessel
installation. In any case keep, a min. distance
of 300 mm.