34

VEGAFLEX 51P and 52P

Address

First choose a free bus address (see chap-
ter 3.2 Sensor address").

Adjustment steps

On the following pages you see the menu
schematic of the adjustment module MINI-
COM.

Set up the sensor in the following sequence.
The numbers are stated near the appropriate
menu items in the menu schematic on the
following pages.

1. Adjustment
2. Conditioning
3. Outputs
4. Operating range
5. Meas. conditions
6. Indication of the useful and noise level

1. Adjustment

Under the menu item "

Adjustment" you inform

the sensor with which span it should work.

Setup

Max.

Min.

100 % (distance to the medium
0.300 m) corresponds to
1200 l

Span

0 % (distance to the medium
5.850 m) corresponds to 456 l

Ad-
just-
ment

Para-
meter
adjust-
ment

Sensor

m(d)

4.700

without
medium

Ad-
just-
ment
in

m(d)

0.0 %

at

m (d)

XX.XXX

(min. adjustment)

OK

OK

OK

OK

1)

Adjustment without medium
• Enter with the "

+" and "–" key the distance

to the medium your sensor has at 0 %
filling (example: 5.850 m)
If you do not know the distance, you have
to do a sounding.

• Enter the distance to the medium which

your sensor has at 100 % filling.

Key

Display

1)

In case of two values which can be modified, you
can move with the "OK" key to the second value.

Adjustment with medium
Fill the vessel e.g. to 10 %, enter in the menu
"

Min. adjustment" with the "+" and "–" keys 10

% and confirm with the "OK" key. Then fill the
vessel e.g. 80 % or 100 %, enter in the menu
"

Max. adjustment" with the "+" and "–" keys 80

% or 100 % and confirm with the "OK" key.

You can carry out the adjustment without
medium. Generally, you will carry out the
adjustment without medium, since you can
adjust without filling the vessel.

with
medium

Min.
adjust
at %

XXX.X

Max.
adjust
at %

XXX.X

Advertising