Capacitive electrodes EK with signal conditioning instrument

Oscillators in two-wire technology for capacitive electrodes EK

Type

Application

Meas. range

Frequency Signal cond.instr.

E14

Level detection in general

I: 0 … 25 pF

400 kHz

VEGATOR

II: 0 … 100 pF

VEGALOG

III: 0 … 400 pF

E15

Level detection in general

I: 0 … 25 pF

400 kHz

VEGATOR

with potential separation

II: 0 … 100 pF

VEGALOG

III: 0 … 400 pF

E15 Ex

as E15, however for use in

I: 0 … 25 pF

400 kHz

VEGATOR Ex

hazardous areas acc. to

II: 0 … 100 pF

VEGALOG

1)

CENELEC, PTB zone 0 as well as

III: 0 … 400 pF

zone 1 and StEx zone 10 and as
part of an overfill protection acc. to
WHG, (VbF)

E17

Continuous level measurement in

I: 0 … 120 pF

40 kHz

VEGAMET

general or level detection with

II: 0 … 600 pF

VEGALOG

potential separation

III: 0 … 3000 pF

(VEGATOR)

E17 Ex

as E17, however for use in

I: 0 … 120 pF

40 kHz

VEGAMET Ex

hazardous areas acc. to

II: 0 … 600 pF

VEGALOG

1)

CENELEC, PTB zone 0 as well as

III: 0 … 3000 pF

(VEGATOR Ex)

zone 1 and StEx zone 10 and as
part of an overfill protection acc. to
WHG, (VbF)

E18

2)

Continuous level measurement

I: 0 … 120 pF

470 kHz

VEGAMET

or level detection with potential

II: 0 … 600 pF

VEGALOG

separation acc. to the principle of

III: 0 … 3000 pF

(VEGATOR)

phase selective admittance proces-
sing especially for adhesive mediums
and for the use in solids with
varying humidity

E18 Ex

2)

as E18, however for the use in

I: 0 … 120 pF

470 kHz

VEGAMET Ex

hazardous areas acc. to

II: 0 … 600 pF

VEGALOG

1)

CENELEC, PTB zone 0 as well as

III: 0 … 3000 pF

(VEGATOR Ex)

zone 1 and StEx zone 10 and as
part of an overfill protection acc. to
WHG, (VbF)

1)

with safety barrier

2)

see following page