Material cone – VEGA Capacitive electrodes EK … with signal conditioning instrument User Manual

Page 22

Advertising
background image

22

Capacitive electrodes EK with signal conditioning instrument

Mounting

Filling

Emptying

Fig. 2.8 Material cone, filling and emptying centered

3

1

2

Filling

Emptying

1 Emptying
2 Filling opening
3 Capacitive

electrode

Fig. 2.9 Material cone, filling centered, emptying laterally

Material cone

Note when installing the electrodes into the
vessel, that material cones can be caused
with solids which can change the switch
point. We recommend to choose an installa-
tion place where the electrode detects an
average value of the material cone.

According to the position of the filling and
emptying opening in the vessel, the electrode
must be installed appropriately. To compen-
sate the measuring errors caused by the
material cone, you should install the electrode
at a distance of

d

/

6

from the vessel wall.

Advertising