6 type plate, Vega, Ek 11 – VEGA Capacitive electrodes EK … with signal conditioning instrument User Manual

Page 17

Advertising
background image

Capacitive electrodes EK with signal conditioning instrument

17

Product description

1.6 Type plate

Before mounting and electrical connection
please check if you use the suitable instru-
ment. Therefore note the type plate which is
located as follows:

Type plate

The type plate contains important data re-
quired for mounting and connection. The
configuration and components of the type
plate are hence explained in the following
example.

1 Master data of the order no.
2 Ex-certification number

Explosion protection version - note the
information and regulations of the certificate

3 Data of the electronics / Approvals
4 No. of the order confirmation/Pos.-no.
5 Number of the electrode type
6 Serial number
7 Test mark when used as part of an overfill

protection for vessels storing water endan-
gering liquids - note the information and
regulations of the general type approval

8 Manufacturing year
9 Number of the test authority

Configuration of the type plate (example)

Order code

Detailed information on the order code you
will find in the "Product Information Capaciti-
ve“ or in the "VEGA-Pricelist“.

6

3

1

4

2

5

Z-65.13.XXX

7

VEGA

®

EK 11

type EK11EXO.XGBVSTXXVKXX

see PTB no. EX-98.E.2085 EEx ia IIC T6

0032

PTB 98 ATEX 2086

II 1/2G EEx ia IIC T6

techn. data see document. / certificates

1998

protection:

IP 66/67 Insp.

length: 400mm

VVO: 02

Ord. no. 123456/000

®

D-77757 Schiltach

8

9

Advertising