3 wiring plan – VEGA VEGAWELL 72 4 … 20 mA User Manual
Page 20
4
I
nsert the wire ends into the open terminals according to
the wiring plan
5
T
ighten the screws with a screwdriver
6
C
heck the hold of the wires in the terminals by lightly
pulling on them
7
T
ighten the compression nut of the cable entry. The seal
ring must completely encircle the cable
8
R
etighten the housing cover
T
he electrical connection is finished.
5
.3 Wiring plan
4
1
2
2
3
Fig. 7: Wire assignment, suspension cable
1
blue (-): to power supply or to the processing system
2
brown (+): to power supply or to the processing system
3
Shielding
4
Breather capillaries with filter element
1
2
–
+
1
2
3
4
5
6
1
2
3
4
5
6
Fig. 8: Terminal assignment VEGABOX 02
1
To power supply or the processing system
2
Shielding
4
)
4)
C
onnect screen to ground terminal. Connect ground terminal on the outside
of the housing as prescribed. The two terminals are galvanically connected.
Direct connection
Connection via
VEGABOX 02
20
VEGAWELL
72 • 4 … 20
mA
5 C
onnecting to power supply
27501
-EN
-080806